SETUP OF VIRTUAL EXPERIMENTS AND CRITICAL ANALYSIS OF CONVENTIONAL THERMOECONOMIC DIAGNOSIS OF MULTIPLE FAULTS IN AIR-CONDENSED ROOFTOP SYSTEMS
2012
The diagnosis of soft faults in vapor compression cooling systems is a crucial activity, since malfunctions may provoke heavy degradation in plant performance and increase the power consumption for space cooling. Among the various Faults Detection and Diagnosis techniques developed over the last two decades, thermoeconomic diagnosis has been playing only a marginal role due to the difficulties encountered when applying the conventional thermoeconomic approaches to vapor compression refrigeration plants. In this paper a critical analysis on capabilities and limits of thermoeconomic diagnosis of refrigeration systems is proposed. The reference plant assumed for this study is a 116 kWc air-con…
Critical analysis of conventional thermoeconomic approaches to the diagnosis of multiple faults in air conditioning units: Capabilities, drawbacks an…
2013
Abstract Faults diagnosis in air conditioning systems is a crucial activity, since malfunctions may induce heavy degradation of performance. Among the available techniques, thermoeconomic diagnosis has played a marginal role due to the difficulties encountered when applying the methodology to refrigeration plants. In this paper a critical analysis on capabilities and limits of thermoeconomic diagnosis is proposed. The reference plant is a 120 kWc air-cooled air conditioning system; a simulator is used to evaluate thermodynamic data under normal and faulty conditions, setting up “virtual experiments” to simulate each fault. Five malfunctions are imposed, either individually or simultaneously…
Thermoeconomic diagnosis of air conditioning systems: experimental assessment of performance for improved reliability
2018
Thermoeconomic diagnosis is an exergy-based fault detection and diagnosis technique which has been recently extended to air conditioning systems. So far, developments of this technique have relied only on simulation data without being evaluated using real data. For the first time, this work aims at assessing the performance of thermoeconomic diagnosis using experimental data obtained from a five-ton packaged rooftop air conditioning unit (RTU) installed at Herrick Laboratories, Purdue University. The RTU was tested in psychrometric chambers under a wide range of operating conditions and fault levels. The following faults were investigated: (i) evaporator fouling, (ii) condenser fouling and …